SYMBOL STANDARD NO. OF CONDUCTORS VOLTAGE CONDUCTOR CROSSSECTION [in mm2]
IB-YSLY IB-YSLY-P ZN-ELT-15 1 ÷ 75 2x2- 20x2 300/500V 0,5 ÷ 2,5 0,5 ÷ 2,5

Application

Cables with stranded copper conductors, PVC insulated and sheathed, with oilresistant, UVresistant, selfextinguishing and fireretardant sheath (LOI > 29). Cable with paired conductors (P), reducing the interaction between the transmitted signals and the impact of external interference on these signals. Designed for operation in intrinsically safe systems and hazardous areas, for 300/500 V operating voltage.
SYMBOL STANDARD NO. OF CONDUCTORS VOLTAGE CONDUCTOR CROSSSECTION [in mm2]
IB-YSL(St)Y IB-YSL(St)Y-P ZN-ELT-15 1 ÷ 75 2x2- 20x2 300/500V 0,5 ÷ 2,5 0,5 ÷ 2,5

Application

Same as IBYSLY + AluPET tape screen for protection against external electromagnetic interference with the transmitted signal and prevention of the emission of interference from the cable.
SYMBOL STANDARD NO. OF CONDUCTORS VOLTAGE CONDUCTOR CROSSSECTION [in mm2]
IB-YSLCY IB-YSLCY-P ZN-ELT-15 1 ÷ 75 2x2- 20x2 300/500V 0,5 ÷ 2,5 0,5 ÷ 2,5

Application

Same as IBYSLY + tinned copper wire braid screen for protection against external electromagnetic interference with the transmitted signal and prevention of the emission of interference from the cable.
SYMBOL STANDARD NO. OF CONDUCTORS VOLTAGE CONDUCTOR CROSSSECTION [in mm2]
IB-YSLYCY IB-YSLYCY-P ZN-ELT-15 1 ÷ 75 2x2- 20x2 300/500V 0,5 ÷ 2,5 0,5 ÷ 2,5

Application

Same as IBYSLCY + extruded inner sheath under the tinned wire screen.
SYMBOL STANDARD NO. OF CONDUCTORS VOLTAGE CONDUCTOR CROSSSECTION [in mm2]
IB-YSLY IB-YSLY-P ZN-ELT-15 1 ÷ 75 2x2- 20x2 0,6/1kV 0,75 ÷ 2,5 0,75 ÷ 2,5

Application

Cables with stranded copper conductors, PVC insulated and sheathed, with oilresistant, UVresistant, selfextinguishing and fireretardant sheath (LOI > 29). Cable with paired conductors (P), reducing the interaction between the transmitted signals and the impact of external interference on these signals. Designed for operation in intrinsically safe systems and hazardous areas, for 300/500 V operating voltage.
SYMBOL STANDARD NO. OF CONDUCTORS VOLTAGE CONDUCTOR CROSSSECTION [in mm2]
IB-YSL(St)Y IB-YSL(St)Y-P ZN-ELT-15 1 ÷ 75 2x2- 20x2 0,6/1kV 0,75 ÷ 2,5 0,75 ÷ 2,5

Application

Same as IBYSLY + AluPET tape screen for protection against external electromagnetic interference with the transmitted signal and prevention of the emission of interference from the cable.
SYMBOL STANDARD NO. OF CONDUCTORS VOLTAGE CONDUCTOR CROSSSECTION [in mm2]
IB-YSLCY IB-YSLCY-P ZN-ELT-15 1 ÷ 75 2x2- 20x2 0,6/1kV 0,75 ÷ 2,5 0,75 ÷ 2,5

Application

Same as IBYSLY + tinned copper wire braid screen for protection against external electromagnetic interference with the transmitted signal and prevention of the emission of interference from the cable.
SYMBOL STANDARD NO. OF CONDUCTORS VOLTAGE CONDUCTOR CROSSSECTION [in mm2]
IB-YSLYCY IB-YSLYCY-P ZN-ELT-15 1 ÷ 75 2x2- 20x2 0,6/1kV 0,75 ÷ 2,5 0,75 ÷ 2,5

Application

Same as IBYSLCY + extruded inner sheath under the tinned wire screen.