SYMBOL | STANDARD | NO. OF CONDUCTORS | VOLTAGE | CONDUCTOR CROSSSECTION [in mm2] |
---|---|---|---|---|
IB-YSLY IB-YSLY-P | ZN-ELT-15 | 1 ÷ 75 2x2- 20x2 | 300/500V | 0,5 ÷ 2,5 0,5 ÷ 2,5 |
Application
Cables with stranded copper conductors, PVC insulated and sheathed, with oilresistant, UVresistant, selfextinguishing and fireretardant sheath (LOI > 29). Cable with paired conductors (P), reducing the interaction between the transmitted signals and the impact of external interference on these signals. Designed for operation in intrinsically safe systems and hazardous areas, for 300/500 V operating voltage.SYMBOL | STANDARD | NO. OF CONDUCTORS | VOLTAGE | CONDUCTOR CROSSSECTION [in mm2] |
---|---|---|---|---|
IB-YSL(St)Y IB-YSL(St)Y-P | ZN-ELT-15 | 1 ÷ 75 2x2- 20x2 | 300/500V | 0,5 ÷ 2,5 0,5 ÷ 2,5 |
Application
Same as IBYSLY + AluPET tape screen for protection against external electromagnetic interference with the transmitted signal and prevention of the emission of interference from the cable.SYMBOL | STANDARD | NO. OF CONDUCTORS | VOLTAGE | CONDUCTOR CROSSSECTION [in mm2] |
---|---|---|---|---|
IB-YSLCY IB-YSLCY-P | ZN-ELT-15 | 1 ÷ 75 2x2- 20x2 | 300/500V | 0,5 ÷ 2,5 0,5 ÷ 2,5 |
Application
Same as IBYSLY + tinned copper wire braid screen for protection against external electromagnetic interference with the transmitted signal and prevention of the emission of interference from the cable.SYMBOL | STANDARD | NO. OF CONDUCTORS | VOLTAGE | CONDUCTOR CROSSSECTION [in mm2] |
---|---|---|---|---|
IB-YSLYCY IB-YSLYCY-P | ZN-ELT-15 | 1 ÷ 75 2x2- 20x2 | 300/500V | 0,5 ÷ 2,5 0,5 ÷ 2,5 |
Application
Same as IBYSLCY + extruded inner sheath under the tinned wire screen.SYMBOL | STANDARD | NO. OF CONDUCTORS | VOLTAGE | CONDUCTOR CROSSSECTION [in mm2] |
---|---|---|---|---|
IB-YSLY IB-YSLY-P | ZN-ELT-15 | 1 ÷ 75 2x2- 20x2 | 0,6/1kV | 0,75 ÷ 2,5 0,75 ÷ 2,5 |
Application
Cables with stranded copper conductors, PVC insulated and sheathed, with oilresistant, UVresistant, selfextinguishing and fireretardant sheath (LOI > 29). Cable with paired conductors (P), reducing the interaction between the transmitted signals and the impact of external interference on these signals. Designed for operation in intrinsically safe systems and hazardous areas, for 300/500 V operating voltage.SYMBOL | STANDARD | NO. OF CONDUCTORS | VOLTAGE | CONDUCTOR CROSSSECTION [in mm2] |
---|---|---|---|---|
IB-YSL(St)Y IB-YSL(St)Y-P | ZN-ELT-15 | 1 ÷ 75 2x2- 20x2 | 0,6/1kV | 0,75 ÷ 2,5 0,75 ÷ 2,5 |
Application
Same as IBYSLY + AluPET tape screen for protection against external electromagnetic interference with the transmitted signal and prevention of the emission of interference from the cable.SYMBOL | STANDARD | NO. OF CONDUCTORS | VOLTAGE | CONDUCTOR CROSSSECTION [in mm2] |
---|---|---|---|---|
IB-YSLCY IB-YSLCY-P | ZN-ELT-15 | 1 ÷ 75 2x2- 20x2 | 0,6/1kV | 0,75 ÷ 2,5 0,75 ÷ 2,5 |
Application
Same as IBYSLY + tinned copper wire braid screen for protection against external electromagnetic interference with the transmitted signal and prevention of the emission of interference from the cable.SYMBOL | STANDARD | NO. OF CONDUCTORS | VOLTAGE | CONDUCTOR CROSSSECTION [in mm2] |
---|---|---|---|---|
IB-YSLYCY IB-YSLYCY-P | ZN-ELT-15 | 1 ÷ 75 2x2- 20x2 | 0,6/1kV | 0,75 ÷ 2,5 0,75 ÷ 2,5 |
Application
Same as IBYSLCY + extruded inner sheath under the tinned wire screen.Usage
> Bare solid and stranded copper wires
> Control cables, flexible, PVC insulated and sheathed
> Low smoke zero halogen armoured power cables
> Low smoke zero halogen power cables
> Power cables with concentric conductor
> Singleconductor heatresistant wiring cables with rubber insulation
> Singleconductor wiring cables insulated with zero halogen compound insulation