Eltrim Kable Sp. z o.o. | Producent przewodów elektrycznych

Facebook +48 23 697 03 00

Power cables with concentric conductor

SYMBOLSTANDARDNO. OF CONDUCTORSVOLTAGECONDUCTOR CROSSSECTION [in mm2]
NYCYDIN VDE 0276-603
DIN VDE 0276-627
2 ÷ 5
3 ÷ 4
7 ÷ 61
7 ÷ 19
0,6/1kV1,5 ÷ 16
25 ÷ 240
1,5 ÷ 2.5
4
NAYCYDIN VDE 0276-6033 ÷ 40,6/1kV16 ÷ 50
PFSPPN-HD 603 S1
NEMKO 182.52
2 ÷ 4
3; 4
0,6/1kV2,5 ÷ 16 Cu
16 ÷ 240 Cu
16 ÷ 240 Al.

Application

Power cables with OVC insulation and PVC sheath with a concentric conductor from circular copper wires, designed for industrial systems and switching stations where high level of electrical safety and mechanical protection is required. Directburied or installed in cable ducts, indoors and outdoors.

SYMBOLSTANDARDNO. OF CONDUCTORSVOLTAGECONDUCTOR CROSSSECTION [in mm2]
TFSPPN-HD 603 S1
NEMKO 182.52
3; 40,6/1kV16 ÷ 240
Al
16 ÷ 240
Cu

Application

Cables with XLPE insulation and PVC coating with a copper concentric conductor, designed for power lines.

SYMBOLSTANDARDNO. OF CONDUCTORSVOLTAGECONDUCTOR CROSSSECTION [in mm2]
EKKJ
FKKJ
SS 424 14 18
PN-HD 603 S1
1
2
3 ÷ 4
0,6/1kV2,5 ÷ 630
2,5 ÷ 16
2,5 ÷ 240
AKKJSS 424 14 18
PN-HD 603 S1
1
3 ÷ 4
0,6/1kV16 ÷ 630
16 ÷ 240
MCMKPN-HD 603 S1/A2
SFS 4880
1
2
3
4
0,6/1kV1,5 ÷ 10
1,5 ÷ 300
1,5 ÷ 16
AMCMKPN-HD 603 S1/A2
SFS 4880
3
4
0,6/1kV16 ÷ 300
35 ÷ 185

Application

PVC insulated and sheathed power cables with a concentric conductor made from circular copper wires, armoured, designed for electricity transmission, directburied, suspended in the air or installed in cable ducts, indoors and outdoors.

SYMBOLSTANDARDNO. OF CONDUCTORSVOLTAGECONDUCTOR CROSSSECTION [in mm2]
YKYeky
YKYekyn
YnKYekyn
yKYekY
yKYekYn
ynKYekYn
PN-93/E-90400
PN-HD 603 S1
IEC 60502-1
2
3
4
5
0,6/1kV 1 ÷ 16
1 ÷ 16
1 ÷ 16
1 ÷ 10

Application

Copper cables with PVC insulation and: – YKYeky cables with inner PVC sheath, copper wire screen and PVC jacket. – yKYekY cables with filling sheath, copper wire screen and outer PVC sheath. – yn, Yn – fireretardant. They are designed for instrumentation and control devices used in the power industry and for electricity transmission in conditions where the transmitted signals have to be protected against external interference and where the emission of interference from the cable has to be limited. Installation: in cable ducts, on structures and directly in the ground, in areas with high exposure to mechanical stresses.

Kontynuując przeglądanie strony wyrażasz zgodę na używanie przez nas plików cookies oraz zapoznałeś się z informacją o przetwarzaniu danych osobowych. Więcej informacji