SYMBOLSTANDARDNO. OF CONDUCTORSVOLTAGECONDUCTOR CROSSSECTION [in mm2]
YAKY
YnAKY
YAKyY
PN-93/E-90401
PN-HD 603 S1
IEC 60502-1
1
3 ÷ 4
5
0,6/1kV10 ÷ 1000
10 ÷ 300
10 ÷ 300

Application

Power cables with aluminium conductors, PVC insulated and sheathed. They are designed to be buried or installed in cable ducts for power plants, the industry, switchgear and local networks.

SYMBOLSTANDARDNO. OF CONDUCTORSVOLTAGECONDUCTOR CROSSSECTION [in mm2]
YAKXS
YnAKXS
YAKyXS
PN-HD 603 S1
IEC-60502-1
1
3 ÷ 4
5
0,6/1kV10 ÷ 300
10 ÷ 120
10 ÷ 35

Application

Power cable with aluminium conductors, with crosslinked polyethylene insulation and PVC sheath. They are designed to be buried or installed in cable ducts for power plants, the industry, switchgear and local networks.

SYMBOLSTANDARDNO. OF CONDUCTORSVOLTAGECONDUCTOR CROSSSECTION [in mm2]
NAYY
(N)AYYö
DIN VDE 0276-603
PN-HD 603 S1
1
3 ÷ 4
0,6/1kV10 ÷ 1000
10 ÷ 300

Application

Power cables with aluminium conductors, PVC insulated and sheathed. They are designed to be buried or installed in cable ducts for power plants, the industry, switchgear and local networks. ö – oilresistant sheath.

SYMBOLSTANDARDNO. OF CONDUCTORSVOLTAGECONDUCTOR CROSSSECTION [in mm2]
NA2XY
(N)A2XY-FR
DIN VDE 0276-603
PN-HD 603 S1
1
3 ÷ 4
0,6/1kV10 ÷ 1000
10 ÷ 300

Application

Power cables with aluminium conductors, with crosslinked polyethylene insulation and PVC sheath. They are designed to be buried or installed in cable ducts for power plants, the industry, switchgear and local networks. FR – fireretardant sheath.

SYMBOLSTANDARDNO. OF CONDUCTORSVOLTAGECONDUCTOR CROSSSECTION [in mm2]
NA2XY
(N)A2XY-FR
DIN VDE 0276-603
PN-HD 603 S1
1
3 ÷ 4
0,6/1kV10 ÷ 1000
10 ÷ 300

Application

Power cables with aluminium conductors, with crosslinked polyethylene insulation and PVC sheath. They are designed to be buried or installed in cable ducts for power plants, the industry, switchgear and local networks. FR – fireretardant sheath.

SYMBOLSTANDARDNO. OF CONDUCTORSVOLTAGECONDUCTOR CROSSSECTION [in mm2]
NAY2Y-O
NAY2Y-J
PN-HD 603 S11
3 ÷ 4
5
0,6/1kV10 ÷ 500
1,5 ÷ 240
1,5 ÷ 240

Application

Power cable with aluminium conductors, with PVC insulation and PE sheath. Designed to be installed indoors and outdoors, buried or laid in cable ducts or concrete, for electricity transmission.

SYMBOLSTANDARDNO. OF CONDUCTORSVOLTAGECONDUCTOR CROSSSECTION [in mm2]
U-1000 AR2VNEC 32-3211
3 ÷ 4
5
0,6/1kV10 ÷ 1000
10 ÷ 300
10 ÷ 300

Application

Power cables with aluminium conductors, with crosslinked polyethylene insulation and PVC sheath. They are designed for standard industrial systems or power columns of buildings.

SYMBOLSTANDARDNO. OF CONDUCTORSVOLTAGECONDUCTOR CROSSSECTION [in mm2]
CABT
CABT-c
BDS 16291-851
2
3 ÷ 5
0,6/1kV6 ÷ 630
6 ÷ 25
6 ÷ 300

Application

Power cables with aluminium conductors, PVC insulated and sheathed. They are designed to be buried or installed in cable ducts for power plants, the industry, switchgear and local networks.

SYMBOLSTANDARDNO. OF CONDUCTORSVOLTAGECONDUCTOR CROSSSECTION [in mm2]
1-AYKYCSN 34 7659-3A
IEC 60502-1
1
3 ÷ 4
3 ÷ 1
0,6/1kV16 ÷ 630
16 ÷ 240
25+16 do 300+150

Application

KPower cables with aluminium conductors, PVC insulated and sheathed, designed for electricity transmission in buried power lines. They may also be installed indoors, in cable ducts and outdoors.

SYMBOLSTANDARDNO. OF CONDUCTORSVOLTAGECONDUCTOR CROSSSECTION [in mm2]
XAKXS
XnAKXS
XAKyXS
NA2X2Y
(N)A2X2Y-FR
IEC 60502-1
HD 603 S1
DIN VDE 0276-603
1
3 ÷ 5
0,6/1kV10 ÷ 1000
10 ÷ 300

Application

Power cables with aluminium conductors, with crosslinked polyethylene insulation and thermoplastic polyethylene sheath. They are designed to be buried or installed in cable ducts for power plants, the industry, switchgear and local networks. Xn – fireretardant sheath, y – EPDM filling.

Kontynuując przeglądanie strony wyrażasz zgodę na używanie przez nas plików cookies. Więcej informacji