Eltrim Kable Sp. z o.o. | Producent przewodów elektrycznych

Facebook +48 23 697 03 00

Intrinsically safe control cables

SYMBOLSTANDARDNO. OF CONDUCTORSVOLTAGECONDUCTOR CROSSSECTION [in mm2]
IB-YSLY
IB-YSLY-P
ZN-ELT-151 ÷ 75
2×2-
20×2
300/500V0,5 ÷ 2,5
0,5 ÷ 2,5

Application

Cables with stranded copper conductors, PVC insulated and sheathed, with oilresistant, UVresistant, selfextinguishing and fireretardant sheath (LOI > 29). Cable with paired conductors (P), reducing the interaction between the transmitted signals and the impact of external interference on these signals. Designed for operation in intrinsically safe systems and hazardous areas, for 300/500 V operating voltage.

SYMBOLSTANDARDNO. OF CONDUCTORSVOLTAGECONDUCTOR CROSSSECTION [in mm2]
IB-YSL(St)Y
IB-YSL(St)Y-P
ZN-ELT-151 ÷ 75
2×2-
20×2
300/500V0,5 ÷ 2,5
0,5 ÷ 2,5

Application

Same as IBYSLY + AluPET tape screen for protection against external electromagnetic interference with the transmitted signal and prevention of the emission of interference from the cable.

SYMBOLSTANDARDNO. OF CONDUCTORSVOLTAGECONDUCTOR CROSSSECTION [in mm2]
IB-YSLCY
IB-YSLCY-P
ZN-ELT-151 ÷ 75
2×2-
20×2
300/500V0,5 ÷ 2,5
0,5 ÷ 2,5

Application

Same as IBYSLY + tinned copper wire braid screen for protection against external electromagnetic interference with the transmitted signal and prevention of the emission of interference from the cable.

SYMBOLSTANDARDNO. OF CONDUCTORSVOLTAGECONDUCTOR CROSSSECTION [in mm2]
IB-YSLYCY
IB-YSLYCY-P
ZN-ELT-151 ÷ 75
2×2-
20×2
300/500V0,5 ÷ 2,5
0,5 ÷ 2,5

Application

Same as IBYSLCY + extruded inner sheath under the tinned wire screen.

SYMBOLSTANDARDNO. OF CONDUCTORSVOLTAGECONDUCTOR CROSSSECTION [in mm2]
IB-YSLY
IB-YSLY-P
ZN-ELT-151 ÷ 75
2×2-
20×2
0,6/1kV0,75 ÷ 2,5
0,75 ÷ 2,5

Application

Cables with stranded copper conductors, PVC insulated and sheathed, with oilresistant, UVresistant, selfextinguishing and fireretardant sheath (LOI > 29). Cable with paired conductors (P), reducing the interaction between the transmitted signals and the impact of external interference on these signals. Designed for operation in intrinsically safe systems and hazardous areas, for 300/500 V operating voltage.

SYMBOLSTANDARDNO. OF CONDUCTORSVOLTAGECONDUCTOR CROSSSECTION [in mm2]
IB-YSL(St)Y
IB-YSL(St)Y-P
ZN-ELT-151 ÷ 75
2×2-
20×2
0,6/1kV0,75 ÷ 2,5
0,75 ÷ 2,5

Application

Same as IBYSLY + AluPET tape screen for protection against external electromagnetic interference with the transmitted signal and prevention of the emission of interference from the cable.

SYMBOLSTANDARDNO. OF CONDUCTORSVOLTAGECONDUCTOR CROSSSECTION [in mm2]
IB-YSLCY
IB-YSLCY-P
ZN-ELT-151 ÷ 75
2×2-
20×2
0,6/1kV0,75 ÷ 2,5
0,75 ÷ 2,5

Application

Same as IBYSLY + tinned copper wire braid screen for protection against external electromagnetic interference with the transmitted signal and prevention of the emission of interference from the cable.

SYMBOLSTANDARDNO. OF CONDUCTORSVOLTAGECONDUCTOR CROSSSECTION [in mm2]
IB-YSLYCY
IB-YSLYCY-P
ZN-ELT-151 ÷ 75
2×2-
20×2
0,6/1kV0,75 ÷ 2,5
0,75 ÷ 2,5

Application

Same as IBYSLCY + extruded inner sheath under the tinned wire screen.