SYMBOL |
STANDARD |
NO. OF CONDUCTORS |
VOLTAGE |
CONDUCTOR CROSSSECTION [in mm2] |
YKYFty
YKYFtyn
YnKYFtyn
yKYFtY
yKYFtYn |
PN-93/E-90401
IEC 60502-1 |
2
3 ÷ 4
5 |
0,6/1kV |
1,5 ÷ 50
1,5 ÷ 300
1,5 ÷ 240 |
YAKYFty
YAKYFtyn
YAnKYFtyn
yAKYFtY
yAKYFtYn |
PN-93/E-90401
IEC 60502-1 |
3
4
3 + 1 |
0,6/1kV |
10 ÷ 300
10 ÷ 300
25+16 do 300+150 |
Application
Power cables with PVC insulation, filling sheath, armoured with steel tapes, and PVC outer sheath. Designed for the electrical power industry, for indoor and outdoor installation, in overhead lines, in cable ducts and directly in the ground, in areas with high exposure to mechanical stresses. Yn – fireretardant outer sheath. Ft – armour from galvanised steel tapes. Ftl – armour from painted steel tapes.
SYMBOL |
STANDARD |
NO. OF CONDUCTORS |
VOLTAGE |
CONDUCTOR CROSSSECTION [in mm2] |
YKYFoy
YKYFoyn
YnKYFoyn
yKYFoY
yKYFoYn
YKYFpy
YKYFpyn
YnKYFpyn
yKYFpY
yKYFpYn |
PN-93/E-90401
IEC 60502-1 |
2
3 ÷ 4
5
3+1 |
0,6/1kV |
1,5 ÷ 50
1,5 ÷ 300
1,5 ÷ 240
25+16 do 300+150 |
Application
Multiconductor power cables with PVC insulated copper conductors, PVC sheath, armour from galvanised circular (Fo) or flat (Fp) steel wires and extruded PVC jacket on the armour. Designed for electricity transmission, e.g., power lines suspended in the air, indoor and outdoor installation, in cable ducts and directly in the ground in areas with high exposure to mechanical stresses.
SYMBOL |
STANDARD |
NO. OF CONDUCTORS |
VOLTAGE |
CONDUCTOR CROSSSECTION [in mm2] |
YAKYFoy
YAKYFoyn
YnAKYFoyn
yAKYFoY
yAKYFoYn
YAKYFpy
YAKYFpyn
YnAKYFpyn
yAKYFpY
yAKYFpYn |
PN-93/E-90401
IEC 60502-1 |
3
4
5
3+1 |
0,6/1kV |
10 ÷ 300
10 ÷ 300
10 ÷ 240
25+16 do 300+150 |
Application
Multiconductor power cables with PVC insulated aluminium conductors, PVC sheath, armour from galvanised circular (Fo) or flat (Fp) steel wires and extruded PVC jacket on the armour. Designed for electricity transmission, e.g., power lines suspended in the air, indoor and outdoor installation, in cable ducts and directly in the ground in areas with high exposure to mechanical stresses.
SYMBOL |
STANDARD |
NO. OF CONDUCTORS |
VOLTAGE |
CONDUCTOR CROSSSECTION [in mm2] |
YKYAoy
YKYAoyn
YnKYAoyn
yKYAoY
yKYAoYn
YAKYAoy
YAKYAoyn
YnAKYAoyn
yAKYAoY
yAKYAoYn |
IEC 60502-1 |
1 |
0,6/1kV |
50 ÷ 1000 |
Application
Singleconductor power cables with PVC insulated copper or aluminium conductors, PVC sheath, armour from galvanised circular (Ao) aluminium wires and extruded PVC jacket on the armour. Designed for electricity transmission, e.g., power lines suspended in the air, indoor and outdoor installation, in cable ducts and directly in the ground in areas with high exposure to mechanical stresses.
SYMBOL |
STANDARD |
NO. OF CONDUCTORS |
VOLTAGE |
CONDUCTOR CROSSSECTION [in mm2] |
YKYektmy
YKYektmyn
YnKYektmyn
yKYektmY
yKYektmYn
ynKYektmYn |
PN-93/E-90400
PN-HD 603 S1
IEC 60502-1 |
2
3
4
5 |
0,6/1kV |
1 ÷ 16
1 ÷ 16
1 ÷ 16
1 ÷ 10 |
Application
Copper cables with PVC insulation and: – YKYektmy cables with inner PVC sheath, Cu tape screen and PVC jacket. – yKYektmY cables with filling sheath, Cu tape screen and outer PVC sheath. – yn, Yn – fireretardant. They are designed for instrumentation and control devices used in the power industry and for electricity transmission in conditions where the transmitted signals have to be protected against external interference and where the emission of interference from the cable has to be limited. Installation: in cable ducts, on structures and directly in the ground, in areas with high exposure to mechanical stresses.
SYMBOL |
STANDARD |
NO. OF CONDUCTORS |
VOLTAGE |
CONDUCTOR CROSSSECTION [in mm2] |
YKSYFty
YKSYFtyn
YnKSYFtyn
yKSYFtY
yKSYFtlY
yKSYFtYn
ynKSYFtYn |
PN-93/E-90403
PN-93/E-90400
PN-HD 627 S1
IEC 60502-1 |
7 ÷ 75
7 ÷ 10 |
0,6/1kV |
1,0 ÷ 2,5
4 ÷ 10 |
Application
Copper signal cables with PVC insulation and: yKSYFtYn – with filling coating, galvanised steel tape armour and PVC outer sheath. YKSYFtyn – with PVC inner sheath, armoured with galvanised steel tapes, and PVC outer sheath. yn, Yn – fireretardant. Ftl – armoured with painted steel tapes. Designed for instrumentation and control devices used in the power industry and for electricity transmission. Installation: in cable ducts, on structures and directly in the ground, in areas with high exposure to mechanical stresses.
SYMBOL |
STANDARD |
NO. OF CONDUCTORS |
VOLTAGE |
CONDUCTOR CROSSSECTION [in mm2] |
YKSYFoy
YKSYFoyn
YnKSYFoyn
yKSYFoY
yKSYFoYn
ynKSYFoYn |
PN-93/E-90403
PN-93/E-90400
PN-HD 627 S1
IEC 60502-1 |
7 ÷ 75
7 ÷ 10 |
0,6/1kV |
1,0 ÷ 2,5
4 ÷ 10 |
Application
Copper signal cables with PVC insulation and: yKSYFoY – with filling coating, galvanised steel wire armour and PVC outer sheath. YKSYFoy – with PVC inner sheath, armoured with galvanised steel wires, and PVC outer sheath. yn, Yn – fireretardant. They are designed for instrumentation and control devices used in the power industry and for electricity transmission. Installation: in cable ducts, on structures and directly in the ground, in areas with high exposure to mechanical stresses.
SYMBOL |
STANDARD |
NO. OF CONDUCTORS |
VOLTAGE |
CONDUCTOR CROSSSECTION [in mm2] |
YKSXSFty
YKSXSFtyn
YnKSXSFtyn
YKSXSFoy
YKSXSFoyn
YnKSXSFoyn |
PN-93/E-90403
PN-93/E-90400
PN-HD 627 S1
IEC 60502-1 |
7 ÷ 75
7 ÷ 10 |
0,6/1kV |
1 ÷ 2,5
4 ÷ 10 |
Application
Copper signal cables with XLPE insulation and: – yKSXSFtYn – with filling sheath, armoured with galvanised steel tapes, with PVC outer sheath. – YKSXSFtyn – with inner filling sheath, armoured with galvanised steel tapes, with PVC outer sheath. – yn, Yn – fireretardant. – Foy – circularwire armour. – Ftl – armour from painted steel tapes. Designed for instrumentation and control devices used in the power industry and for electricity transmission. Installation: in cable ducts, on structures and directly in the ground, in areas with high exposure to mechanical stresses.
SYMBOL |
STANDARD |
NO. OF CONDUCTORS |
VOLTAGE |
CONDUCTOR CROSSSECTION [in mm2] |
YKSYektmy
YKSYektmyn
YnKSYektmyn
yKSYektmY
yKSYektmYn
ynKSYektmYn |
PN-93/E-90400
PN-HD 627
IEC 60502-1 |
7 ÷ 75
7 ÷ 10 |
0,6/1kV |
1 ÷ 2,5
4 ÷ 10 |
Application
Copper signal cables with PVC insulation and: – YKSYektmy cables with inner PVC sheath, Cu tape screen and PVC jacket. – yKSYektmY cables with filling sheath, Cu tape screen and outer PVC sheath. – yn, Yn – fireretardant. They are designed for instrumentation and control devices used in the power industry and for electricity transmission in conditions where the transmitted signals have to be protected against external interference and where the emission of interference from the cable has to be limited. Installation: in cable ducts, on structures and directly in the ground, in areas with high exposure to mechanical stresses.
SYMBOL |
STANDARD |
NO. OF CONDUCTORS |
VOLTAGE |
CONDUCTOR CROSSSECTION [in mm2] |
NYRY |
DIN VDE 0271 |
2 ÷ 5
2 ÷ 40
2 ÷ 19 |
0,6/1kV |
1,5 ÷ 16
1,5 ÷ 2,5
4 |
NYRGY |
DIN VDE 0271 |
4
3+1 |
0,6/1kV |
25 ÷ 300 |
1-CYKYDY |
Adapted to:CSN 34 7615 |
4
4 ÷ 5
4 ÷ 7
3 ÷ 24
3+1 |
0,6/1kV |
25 ÷ 300
6 ÷ 16
4
1,5 ÷ 2,5
25+16÷240+120 |
Application
Power cables with PVC insulation and sheath, armoured with galvanised steel wires, designed for electricity transmission, directburied, installed in cable ducts, indoors and outdoors, where resistance against mechanical damage is required.
SYMBOL |
STANDARD |
NO. OF CONDUCTORS |
VOLTAGE |
CONDUCTOR CROSSSECTION [in mm2] |
NYFGY
NAYFGY |
DIN VDE 0271 |
4
3 ÷ 1 |
0,6/1kV |
35 ÷ 300
25/16 ÷ 300/150 |
Application
Power cables with PVC insulation and sheath, armoured with flat galvanised steel wires.
SYMBOL |
STANDARD |
NO. OF CONDUCTORS |
VOLTAGE |
CONDUCTOR CROSSSECTION [in mm2] |
NYBY |
DIN VDE 0271 |
3 + 5
3 + 1
2 ÷ 40
2 ÷ 19 |
0,6/1kV |
1,5 ÷ 240
25+16 ÷ 240+120
1,5 ÷ 2.54 |
CBbT-c |
BDS 16291-85 |
2
3 ÷ 5
6 ÷ 37
6 ÷ 10 |
0,6/1kV |
1,5 ÷ 16
1,5 ÷ 240
1,5 ÷ 2.5
4 ÷ 10 |
Application
Power cables with PVC insulation, armoured with galvanised steel tapes.
SYMBOL |
STANDARD |
NO. OF CONDUCTORS |
VOLTAGE |
CONDUCTOR CROSSSECTION [in mm2] |
Cu/PVC/AWA/
PVC |
BS 6346
IEC 60502-1 |
1 |
0,6/1kV |
50 ÷ 1000 |
Application
Singleconductor power cables with PVC insulation and sheath, armoured with aluminium wires.
SYMBOL |
NORMA |
LICZBA ŻYŁ |
NAPIĘCIE |
PRZEKRÓJ ŻYŁ [w mm2] |
Cu/PVC/SWA/PVC |
BS 6346
IEC 60502-1 |
2
3 ÷ 4
3 + 1
5
7 ÷ 48
7 ÷ 19 |
0,6/1kV |
1,5 ÷ 240
1,5 ÷ 300
25+16÷300+150
1,5 ÷ 70
1,5 ÷ 2.5
4 |
Application
Multiconductor power cables with PVC insulation and sheath, armoured with galvanised aluminium wires.
SYMBOL |
STANDARD |
NO. OF CONDUCTORS |
VOLTAGE |
CONDUCTOR CROSSSECTION [in mm2] |
Cu/XLPE/PVC/
AWA/PVC |
BS 5467
IEC 60502-1 |
1 |
0,6/1kV |
50 ÷ 1000 |
Application
Singleconductor power cables with XLPE insulation and sheath, armoured with galvanised aluminium wires.
SYMBOL |
STANDARD |
NO. OF CONDUCTORS |
VOLTAGE |
CONDUCTOR CROSSSECTION [in mm2] |
Cu/XLPE/PVC/
SWA/PVC |
BS 5467
IEC 60502-1 |
2÷4
3 + 1
5
7 ÷ 48
7 ÷ 19 |
0,6/1kV |
1,5÷240
25+16 ÷ 240+120
1,5 ÷ 70
1,5 ÷ 2.5
4 |
Application
Multiconductor power cables with XLPE insulation and PVC sheath, armoured with aluminium wires.