SYMBOL STANDARD NO. OF CONDUCTORS VOLTAGE CONDUCTOR CROSSSECTION [in mm2]
YKYFty YKYFtyn YnKYFtyn yKYFtY yKYFtYn PN-93/E-90401 IEC 60502-1 2 3 ÷ 4 5 0,6/1kV 1,5 ÷ 50 1,5 ÷ 300 1,5 ÷ 240
YAKYFty YAKYFtyn YAnKYFtyn yAKYFtY yAKYFtYn PN-93/E-90401 IEC 60502-1 3 4 3 + 1 0,6/1kV 10 ÷ 300 10 ÷ 300 25+16 do 300+150

Application

Power cables with PVC insulation, filling sheath, armoured with steel tapes, and PVC outer sheath. Designed for the electrical power industry, for indoor and outdoor installation, in overhead lines, in cable ducts and directly in the ground, in areas with high exposure to mechanical stresses. Yn – fireretardant outer sheath. Ft – armour from galvanised steel tapes. Ftl – armour from painted steel tapes.
SYMBOL STANDARD NO. OF CONDUCTORS VOLTAGE CONDUCTOR CROSSSECTION [in mm2]
YKYFoy YKYFoyn YnKYFoyn yKYFoY yKYFoYn YKYFpy YKYFpyn YnKYFpyn yKYFpY yKYFpYn PN-93/E-90401 IEC 60502-1 2 3 ÷ 4 5 3+1 0,6/1kV 1,5 ÷ 50 1,5 ÷ 300 1,5 ÷ 240 25+16 do 300+150

Application

Multiconductor power cables with PVC insulated copper conductors, PVC sheath, armour from galvanised circular (Fo) or flat (Fp) steel wires and extruded PVC jacket on the armour. Designed for electricity transmission, e.g., power lines suspended in the air, indoor and outdoor installation, in cable ducts and directly in the ground in areas with high exposure to mechanical stresses.
SYMBOL STANDARD NO. OF CONDUCTORS VOLTAGE CONDUCTOR CROSSSECTION [in mm2]
YAKYFoy YAKYFoyn YnAKYFoyn yAKYFoY yAKYFoYn YAKYFpy YAKYFpyn YnAKYFpyn yAKYFpY yAKYFpYn PN-93/E-90401 IEC 60502-1 3 4 5 3+1 0,6/1kV 10 ÷ 300 10 ÷ 300 10 ÷ 240 25+16 do 300+150

Application

Multiconductor power cables with PVC insulated aluminium conductors, PVC sheath, armour from galvanised circular (Fo) or flat (Fp) steel wires and extruded PVC jacket on the armour. Designed for electricity transmission, e.g., power lines suspended in the air, indoor and outdoor installation, in cable ducts and directly in the ground in areas with high exposure to mechanical stresses.
SYMBOL STANDARD NO. OF CONDUCTORS VOLTAGE CONDUCTOR CROSSSECTION [in mm2]
YKYAoy YKYAoyn YnKYAoyn yKYAoY yKYAoYn YAKYAoy YAKYAoyn YnAKYAoyn yAKYAoY yAKYAoYn IEC 60502-1 1 0,6/1kV 50 ÷ 1000

Application

Singleconductor power cables with PVC insulated copper or aluminium conductors, PVC sheath, armour from galvanised circular (Ao) aluminium wires and extruded PVC jacket on the armour. Designed for electricity transmission, e.g., power lines suspended in the air, indoor and outdoor installation, in cable ducts and directly in the ground in areas with high exposure to mechanical stresses.
SYMBOL STANDARD NO. OF CONDUCTORS VOLTAGE CONDUCTOR CROSSSECTION [in mm2]
YKYektmy YKYektmyn YnKYektmyn yKYektmY yKYektmYn ynKYektmYn PN-93/E-90400 PN-HD 603 S1 IEC 60502-1 2 3 4 5 0,6/1kV 1 ÷ 16 1 ÷ 16 1 ÷ 16 1 ÷ 10

Application

Copper cables with PVC insulation and: – YKYektmy cables with inner PVC sheath, Cu tape screen and PVC jacket. – yKYektmY cables with filling sheath, Cu tape screen and outer PVC sheath. – yn, Yn – fireretardant. They are designed for instrumentation and control devices used in the power industry and for electricity transmission in conditions where the transmitted signals have to be protected against external interference and where the emission of interference from the cable has to be limited. Installation: in cable ducts, on structures and directly in the ground, in areas with high exposure to mechanical stresses.
SYMBOL STANDARD NO. OF CONDUCTORS VOLTAGE CONDUCTOR CROSSSECTION [in mm2]
YKSYFty YKSYFtyn YnKSYFtyn yKSYFtY yKSYFtlY yKSYFtYn ynKSYFtYn PN-93/E-90403 PN-93/E-90400 PN-HD 627 S1 IEC 60502-1 7 ÷ 75 7 ÷ 10 0,6/1kV 1,0 ÷ 2,5 4 ÷ 10

Application

Copper signal cables with PVC insulation and: yKSYFtYn – with filling coating, galvanised steel tape armour and PVC outer sheath. YKSYFtyn – with PVC inner sheath, armoured with galvanised steel tapes, and PVC outer sheath. yn, Yn – fireretardant. Ftl – armoured with painted steel tapes. Designed for instrumentation and control devices used in the power industry and for electricity transmission. Installation: in cable ducts, on structures and directly in the ground, in areas with high exposure to mechanical stresses.
SYMBOL STANDARD NO. OF CONDUCTORS VOLTAGE CONDUCTOR CROSSSECTION [in mm2]
YKSYFoy YKSYFoyn YnKSYFoyn yKSYFoY yKSYFoYn ynKSYFoYn PN-93/E-90403 PN-93/E-90400 PN-HD 627 S1 IEC 60502-1 7 ÷ 75 7 ÷ 10 0,6/1kV 1,0 ÷ 2,5 4 ÷ 10

Application

Copper signal cables with PVC insulation and: yKSYFoY – with filling coating, galvanised steel wire armour and PVC outer sheath. YKSYFoy – with PVC inner sheath, armoured with galvanised steel wires, and PVC outer sheath. yn, Yn – fireretardant. They are designed for instrumentation and control devices used in the power industry and for electricity transmission. Installation: in cable ducts, on structures and directly in the ground, in areas with high exposure to mechanical stresses.
SYMBOL STANDARD NO. OF CONDUCTORS VOLTAGE CONDUCTOR CROSSSECTION [in mm2]
YKSXSFty YKSXSFtyn YnKSXSFtyn YKSXSFoy YKSXSFoyn YnKSXSFoyn PN-93/E-90403 PN-93/E-90400 PN-HD 627 S1 IEC 60502-1 7 ÷ 75 7 ÷ 10 0,6/1kV 1 ÷ 2,5 4 ÷ 10

Application

Copper signal cables with XLPE insulation and: – yKSXSFtYn – with filling sheath, armoured with galvanised steel tapes, with PVC outer sheath. – YKSXSFtyn – with inner filling sheath, armoured with galvanised steel tapes, with PVC outer sheath. – yn, Yn – fireretardant. – Foy – circularwire armour. – Ftl – armour from painted steel tapes. Designed for instrumentation and control devices used in the power industry and for electricity transmission. Installation: in cable ducts, on structures and directly in the ground, in areas with high exposure to mechanical stresses.
SYMBOL STANDARD NO. OF CONDUCTORS VOLTAGE CONDUCTOR CROSSSECTION [in mm2]
YKSYektmy YKSYektmyn YnKSYektmyn yKSYektmY yKSYektmYn ynKSYektmYn PN-93/E-90400 PN-HD 627 IEC 60502-1 7 ÷ 75 7 ÷ 10 0,6/1kV 1 ÷ 2,5 4 ÷ 10

Application

Copper signal cables with PVC insulation and: – YKSYektmy cables with inner PVC sheath, Cu tape screen and PVC jacket. – yKSYektmY cables with filling sheath, Cu tape screen and outer PVC sheath. – yn, Yn – fireretardant. They are designed for instrumentation and control devices used in the power industry and for electricity transmission in conditions where the transmitted signals have to be protected against external interference and where the emission of interference from the cable has to be limited. Installation: in cable ducts, on structures and directly in the ground, in areas with high exposure to mechanical stresses.
SYMBOL STANDARD NO. OF CONDUCTORS VOLTAGE CONDUCTOR CROSSSECTION [in mm2]
NYRY DIN VDE 0271 2 ÷ 5 2 ÷ 40 2 ÷ 19 0,6/1kV 1,5 ÷ 16 1,5 ÷ 2,5 4
NYRGY DIN VDE 0271 4 3+1 0,6/1kV 25 ÷ 300
1-CYKYDY Adapted to:CSN 34 7615 4 4 ÷ 5 4 ÷ 7 3 ÷ 24 3+1 0,6/1kV 25 ÷ 300 6 ÷ 16 4 1,5 ÷ 2,5 25+16÷240+120

Application

Power cables with PVC insulation and sheath, armoured with galvanised steel wires, designed for electricity transmission, directburied, installed in cable ducts, indoors and outdoors, where resistance against mechanical damage is required.
SYMBOL STANDARD NO. OF CONDUCTORS VOLTAGE CONDUCTOR CROSSSECTION [in mm2]
NYFGY NAYFGY DIN VDE 0271 4 3 ÷ 1 0,6/1kV 35 ÷ 300 25/16 ÷ 300/150

Application

Power cables with PVC insulation and sheath, armoured with flat galvanised steel wires.
SYMBOL STANDARD NO. OF CONDUCTORS VOLTAGE CONDUCTOR CROSSSECTION [in mm2]
NYBY DIN VDE 0271 3 + 5 3 + 1 2 ÷ 40 2 ÷ 19 0,6/1kV 1,5 ÷ 240 25+16 ÷ 240+120 1,5 ÷ 2.54
CBbT-c BDS 16291-85 2 3 ÷ 5 6 ÷ 37 6 ÷ 10 0,6/1kV 1,5 ÷ 16 1,5 ÷ 240 1,5 ÷ 2.5 4 ÷ 10

Application

Power cables with PVC insulation, armoured with galvanised steel tapes.
SYMBOL STANDARD NO. OF CONDUCTORS VOLTAGE CONDUCTOR CROSSSECTION [in mm2]
Cu/PVC/AWA/ PVC BS 6346 IEC 60502-1 1 0,6/1kV 50 ÷ 1000

Application

Singleconductor power cables with PVC insulation and sheath, armoured with aluminium wires.
SYMBOL NORMA LICZBA ŻYŁ NAPIĘCIE PRZEKRÓJ ŻYŁ [w mm2]
Cu/PVC/SWA/PVC BS 6346 IEC 60502-1 2 3 ÷ 4 3 + 1 5 7 ÷ 48 7 ÷ 19 0,6/1kV 1,5 ÷ 240 1,5 ÷ 300 25+16÷300+150 1,5 ÷ 70 1,5 ÷ 2.5 4

Application

Multiconductor power cables with PVC insulation and sheath, armoured with galvanised aluminium wires.
SYMBOL STANDARD NO. OF CONDUCTORS VOLTAGE CONDUCTOR CROSSSECTION [in mm2]
Cu/XLPE/PVC/ AWA/PVC BS 5467 IEC 60502-1 1 0,6/1kV 50 ÷ 1000

Application

Singleconductor power cables with XLPE insulation and sheath, armoured with galvanised aluminium wires.
SYMBOL STANDARD NO. OF CONDUCTORS VOLTAGE CONDUCTOR CROSSSECTION [in mm2]
Cu/XLPE/PVC/ SWA/PVC BS 5467 IEC 60502-1 2÷4 3 + 1 5 7 ÷ 48 7 ÷ 19 0,6/1kV 1,5÷240 25+16 ÷ 240+120 1,5 ÷ 70 1,5 ÷ 2.5 4

Application

Multiconductor power cables with XLPE insulation and PVC sheath, armoured with aluminium wires.
Armoured power cables Armoured power cables Armoured power cables Armoured power cables Armoured power cables Armoured power cables Armoured power cables Armoured power cables Armoured power cables Armoured power cables Armoured power cables Armoured power cables Armoured power cables Armoured power cables Armoured power cables Armoured power cables