hhhiuhuih98hhii9
SYMBOL STANDARD NO. OF CONDUCTORS VOLTAGE CONDUCTOR CROSSSECTION [in mm2]
2YSLCY-J UV-2YSLCYK-J ZN-ELT-17 4 0,6/1kV 1,5 ÷ 50

Application

Cables with class5 stranded copper conductors (tinned upon request), polyethylene insulation, screened with AluPET tapes and galvanised wires, and PVC sheath (transparent sheath is available upon request). Designed to connect motors to inverters in industrial equipment, production lines, air conditioning equipment and other equipment, operating in dry and damp rooms. UV2YSLCYKJ – cables with black UVresistant PVC sheath, installed outdoors or buried.
SYMBOL STANDARD NO. OF CONDUCTORS VOLTAGE CONDUCTOR CROSSSECTION [in mm2]
2YSLCY-J (3+) UV-2YSLCYK-J (3+) ZN-ELT-17 4 0,6/1kV 1,5 ÷ 50

Application

Same as 2YSLCY + symmetrical PE conductor – split into three conductors with a reduced crosssection, where the total crosssection of 3 PE conductors corresponds to the crosssection of the phase conductor.
SYMBOL STANDARD NO. OF CONDUCTORS VOLTAGE CONDUCTOR CROSSSECTION [in mm2]
2XSLCY-J UV-2XSLCYK-J ZN-ELT-17 4 0,6/1kV 1,5 ÷ 50

Application

Cables with class5 stranded copper conductors (tinned upon request), crosslinked polyethylene insulation, screened with AluPET tapes and galvanised wires, and PVC sheath (transparent sheath is available upon request). Designed to connect motors to inverters in industrial equipment, production lines, air conditioning equipment and other equipment, operating in dry and damp rooms. UV2XSLCYKJ – cables with black UVresistant PVC sheath, installed outdoors or buried.
SYMBOL STANDARD NO. OF CONDUCTORS VOLTAGE CONDUCTOR CROSSSECTION [in mm2]
2XSLCY-J (3+) UV-2XSLCYK-J (3+) ZN-ELT-17 4 0,6/1kV 1,5 ÷ 50

Application

Same as 2XSLCY + symmetrical PE conductor – split into three conductors with a reduced crosssection, where the total crosssection of 3 PE conductors corresponds to the crosssection of the phase conductor.
SYMBOL STANDARD NO. OF CONDUCTORS VOLTAGE CONDUCTOR CROSSSECTION [in mm2]
2XSLCH-J UV-2XSLCHK-J ZN-ELT-17 4 0,6/1kV 1,5 ÷ 50

Application

Cables with class5 stranded copper conductors (tinned upon request), crosslinked polyethylene insulation, screened with AluPET tapes and galvanised wires, and zero halogen compound sheath characterised by low emission of corrosive gases and smoke during combustion. Designed to connect motors to inverters in industrial equipment, production lines, air conditioning equipment and other equipment, operating in dry and damp rooms, particularly in areas with increased risk of fire. UV2XSLCHKJ – cables with black UVresistant sheath, installed outdoors or buried.
SYMBOL STANDARD NO. OF CONDUCTORS VOLTAGE CONDUCTOR CROSSSECTION [in mm2]
2XSLCH-J (3+) UV-2XSLCHK-J (3+) ZN-ELT-17 4 0,6/1kV 1,5 ÷ 50

Application

Same as 2XSLCH + symmetrical PE conductor – split into three conductors with a reduced crosssection, where the total crosssection of 3 PE conductors corresponds to the crosssection of the phase conductor.
SYMBOL STANDARD NO. OF CONDUCTORS VOLTAGE CONDUCTOR CROSSSECTION [in mm2]
2XSLC11Y-J ZN-ELT-17 4 0,6/1kV 1,5 ÷ 50

Application

Cables with class5 stranded copper conductors (tinned upon request), crosslinked polyethylene insulation, screened with AluPET tapes and galvanised wires, and polyurethane sheath. Designed to connect motors to inverters in industrial equipment, production lines, air conditioning equipment and other equipment, operating in dry and damp rooms, particularly in areas with increased risk of fire, characterised by increased resistance to wear and tear, with high resistance to oil and petrol, resistant to bacteria and UV rays.
SYMBOL STANDARD NO. OF CONDUCTORS VOLTAGE CONDUCTOR CROSSSECTION [in mm2]
2XSLC11Y-J (3+) ZN-ELT-17 4 0,6/1kV 1,5 ÷ 50

Application

Same as 2XSLC11Y + symmetrical PE conductor – split into three conductors with a reduced crosssection, where the total crosssection of 3 PE conductors corresponds to the crosssection of the phase conductor.
Inverter cables Inverter cables Inverter cables Inverter cables
x