SYMBOL STANDARD NO. OF CONDUCTORS VOLTAGE CONDUCTOR CROSSSECTION [in mm2]
NYCY DIN VDE 0276-603 DIN VDE 0276-627 2 ÷ 5 3 ÷ 4 7 ÷ 61 7 ÷ 19 0,6/1kV 1,5 ÷ 16 25 ÷ 240 1,5 ÷ 2.5 4
NAYCY DIN VDE 0276-603 3 ÷ 4 0,6/1kV 16 ÷ 50
PFSP PN-HD 603 S1 NEMKO 182.52 2 ÷ 4 3; 4 0,6/1kV 2,5 ÷ 16 Cu 16 ÷ 240 Cu 16 ÷ 240 Al.

Application

Power cables with OVC insulation and PVC sheath with a concentric conductor from circular copper wires, designed for industrial systems and switching stations where high level of electrical safety and mechanical protection is required. Directburied or installed in cable ducts, indoors and outdoors.
SYMBOL STANDARD NO. OF CONDUCTORS VOLTAGE CONDUCTOR CROSSSECTION [in mm2]
TFSP PN-HD 603 S1 NEMKO 182.52 3; 4 0,6/1kV 16 ÷ 240 Al 16 ÷ 240 Cu

Application

Cables with XLPE insulation and PVC coating with a copper concentric conductor, designed for power lines.
SYMBOL STANDARD NO. OF CONDUCTORS VOLTAGE CONDUCTOR CROSSSECTION [in mm2]
EKKJ FKKJ SS 424 14 18 PN-HD 603 S1 1 2 3 ÷ 4 0,6/1kV 2,5 ÷ 630 2,5 ÷ 16 2,5 ÷ 240
AKKJ SS 424 14 18 PN-HD 603 S1 1 3 ÷ 4 0,6/1kV 16 ÷ 630 16 ÷ 240
MCMK PN-HD 603 S1/A2 SFS 4880 1 2 3 4 0,6/1kV 1,5 ÷ 10 1,5 ÷ 300 1,5 ÷ 16
AMCMK PN-HD 603 S1/A2 SFS 4880 3 4 0,6/1kV 16 ÷ 300 35 ÷ 185

Application

PVC insulated and sheathed power cables with a concentric conductor made from circular copper wires, armoured, designed for electricity transmission, directburied, suspended in the air or installed in cable ducts, indoors and outdoors.
SYMBOL STANDARD NO. OF CONDUCTORS VOLTAGE CONDUCTOR CROSSSECTION [in mm2]
YKYeky YKYekyn YnKYekyn yKYekY yKYekYn ynKYekYn PN-93/E-90400 PN-HD 603 S1 IEC 60502-1 2 3 4 5 0,6/1kV 1 ÷ 16 1 ÷ 16 1 ÷ 16 1 ÷ 10

Application

Copper cables with PVC insulation and: – YKYeky cables with inner PVC sheath, copper wire screen and PVC jacket. – yKYekY cables with filling sheath, copper wire screen and outer PVC sheath. – yn, Yn – fireretardant. They are designed for instrumentation and control devices used in the power industry and for electricity transmission in conditions where the transmitted signals have to be protected against external interference and where the emission of interference from the cable has to be limited. Installation: in cable ducts, on structures and directly in the ground, in areas with high exposure to mechanical stresses.
Power cables with concentric conductor Power cables with concentric conductor Power cables with concentric conductor Power cables with concentric conductor Power cables with concentric conductor Power cables with concentric conductor Power cables with concentric conductor Power cables with concentric conductor