SYMBOL | STANDARD | NO. OF CONDUCTORS | VOLTAGE | CONDUCTOR CROSSSECTION [in mm2] |
---|---|---|---|---|
OMY | PN-91/E-90103 PN-EN 50525-2-11 | 2 ÷ 3 4 ÷ 5 | 300/300V | 0,5 ÷ 1,5 0,5 ÷ 0,75 |
H03VV-F | PN-EN 50525-2-11 VDE 0285-525-2-11 | 2 ÷ 4 | 300/300V | 0,5 ÷ 0,75 |
OMYp | PN-91/E-90103 PN-EN 50525-2-11 | 2 3 | 300/300V | 0,5 ÷ 1,5 0,5 |
H03VVH2-F | PN-EN 50525-2-11 VDE 0285-525-2-11 | 2 | 300/300V | 0,5 ÷ 0,75 |
Application
Flexible “residential” cables for the connection of singlephase appliances under low exposure to mechanical stresses in households, kitchens and office premises.SYMBOL | STANDARD | NO. OF CONDUCTORS | VOLTAGE | CONDUCTOR CROSSSECTION [in mm2] |
---|---|---|---|---|
OWY | PN-91/E-90103 | 2 ÷ 5 7 | 300/500V | 0,5 ÷ 6 1 ÷ 2,5 |
H05VV-F | PN-EN 50525-2-11 VDE 0285-5525-2-11 | 2 ÷ 5 | 300/500V | 0,75 ÷ 4 |
OWYp | PN-91/E-90103 | 2 | 300/500V | 0,75 ÷ 1 |
H05VVH2-F | PN-EN 50525-2-11 VDE 0285-5525-2-11 BS-EN 50525-2-11 | 2 | 300/500V | 0,75 ÷ 1 |
Application
Flexible “workshop” cables for the connection of mobile and portable appliances under medium exposure to mechanical stresses, e.g., in workshops. They may be used under more difficult operating conditions in households (e.g., for washing machines).SYMBOL | STANDARD | NO. OF CONDUCTORS | VOLTAGE | CONDUCTOR CROSSSECTION [in mm2] |
---|---|---|---|---|
H03V2V2-F | DIN VDE 0281-12 PN-EN 50525 | 2 ÷ 5 | 300/300V | 0,75 ÷ 4 |
H05V2V2-F | DIN VDE 0281-12 PN-EN 50525 | 2 ÷ 4 | 300/500V | 0,5 ÷ 0,75 |
H03V2V2H2-F | DIN VDE 0281-12 PN-EN 50525 | 2 | 300/300V | 0,5 ÷ 0,75 |
H05V2V2H2-F | DIN VDE 0281-12 PN-EN 50525 | 2 | 300/500V | 0,75 ÷ 1 |
Application
Flexible cables with heatresistant PVC insulation and sheath. They are designed for the connection of electrical appliances in households and operation at up to 90°C.Usage
> Bare solid and stranded copper wires
> Kable i przewody do specjalnych zastosowań
> Przewody w powłoce poliuretanowej
> Intrinsically safe control cables
> Control cables, flexible, PVC insulated and sheathed
> Kable elektroenergetyczne na napięcie 6/6 kV
> Low smoke zero halogen armoured power cables
> Low smoke zero halogen power cables
> Power cables with concentric conductor
> Kable elektroenergetyczne z żyłami aluminiowymi
> Power and signal cables with copper conductors
> Cables with rubber insulation and sheath
> Zero halogen flexible cables for mobile appliances
> Singleconductor heatresistant wiring cables with rubber insulation
> Singleconductor wiring cables insulated with zero halogen compound insulation