SYMBOL |
STANDARD |
NO. OF CONDUCTORS |
VOLTAGE |
CONDUCTOR CROSSSECTION [in mm2] |
YKOXS |
IEC 60092-353
IEC 60332-3-22 |
1
2,4
3
3+1
5 ÷ 37 |
0,6/1kV |
1 ÷ 300
1 ÷ 50
1 ÷ 120
10+6-50+25
1 ÷ 2,5 |
Application
1–50; 1–120; 10+6–50+25; 1–2.5. Ship power cables with crosslinked PVC insulation and PVC sheath, screened, for fixed installation in electrical systems of vessels.
SYMBOL |
STANDARD |
NO. OF CONDUCTORS |
VOLTAGE |
CONDUCTOR CROSSSECTION [in mm2] |
YKOXSekw |
IEC 60092-353
IEC 60332-3-22 |
1
2,4
3
3+1
5 ÷ 37 |
0,6/1kV |
1 ÷ 300
1 ÷ 50
1 ÷ 120
10+6-50+25
1 ÷ 2,5 |
Application
Ship power cables with crosslinked PVC insulation and PVC sheath, screened, for fixed installation in electrical systems of vessels.
SYMBOL |
STANDARD |
NO. OF CONDUCTORS |
VOLTAGE |
CONDUCTOR CROSSSECTION [in mm2] |
YKOXSuy |
IEC 60092-353
IEC 60332-3-22 |
1
2,4
3
3+1
5 ÷ 37 |
0,6/1kV |
1 ÷ 300
1 ÷ 50
1 ÷ 120
10+6-50+25
1 ÷ 2,5 |
Application
Ship power cables with crosslinked PVC insulation and PVC sheath, armoured with a steel wire braid, for fixed installation in electrical systems of vessels.
SYMBOL |
STANDARD |
NO. OF CONDUCTORS |
VOLTAGE |
CONDUCTOR CROSSSECTION [in mm2] |
NKOXS |
IEC 60092-353
IEC 60332-3-22 |
1
2,4
3
3+1
5 ÷ 37 |
0,6/1kV |
1 ÷ 300
1 ÷ 50
1 ÷ 120
10+6-50+25
1 ÷ 2,5 |
Application
Zero halogen ship cables with crosslinked polyethylene insulation and zero halogen compound sheath characterised by low smoke emission. They are designed for fixed installation in electrical systems of vessels.
SYMBOL |
STANDARD |
NO. OF CONDUCTORS |
VOLTAGE |
CONDUCTOR CROSSSECTION [in mm2] |
NKOXSekw |
IEC 60092-353
IEC 60332-3-22 |
1
2,4
3
3+1
5 ÷ 37 |
0,6/1kV |
1 ÷ 300
1 ÷ 50
1 ÷ 120
10+6-50+25
1 ÷ 2,5 |
Application
Zero halogen ship cables with crosslinked polyethylene insulation and zero halogen compound sheath characterised by low smoke emission, with a common screen from copper wires. They are designed for fixed installation in electrical systems of vessels.
SYMBOL |
STANDARD |
NO. OF CONDUCTORS |
VOLTAGE |
CONDUCTOR CROSSSECTION [in mm2] |
NKOXSuN |
IEC 60092-353
IEC 60332-3-22 |
2
3
4
5,7,10 |
0,6/1kV |
1 ÷ 300
1 ÷ 50
1 ÷ 120
10+6-50+25
1 ÷ 2,5 |
Application
Zero halogen ship cables with crosslinked polyethylene insulation and zero halogen compound sheath characterised by low smoke emission, armoured with a galvanised steel wire braid (su). They are designed for fixed installation in electrical systems of vessels.
SYMBOL |
STANDARD |
NO. OF CONDUCTORS |
VOLTAGE |
CONDUCTOR CROSSSECTION [in mm2] |
YTKOXSekw |
IEC 60092-353
IEC 60332-3-22 |
1
2,4
3
3+1
5 ÷ 37 |
0,6/1kV |
1 ÷ 300
1 ÷ 50
1 ÷ 120
10+6-50+25
1 ÷ 2,5 |
NTKOXSekw |
IEC 60092-353
IEC 60332-3-22 |
1
2,4
3
3+1
5 ÷ 37 |
0,6/1kV |
1 ÷ 300
1 ÷ 50
1 ÷ 120
10+6-50+25
1 ÷ 2,5 |
Application
Ship telecommunication cables, screened, with crosslinked polyethylene insulation and PVC sheath (YTKOXSekw) or zero halogen compound sheath (NTKOXSekw). Designed for connections of telecommunication equipment and devices on ships.