SYMBOL STANDARD NO. OF CONDUCTORS VOLTAGE CONDUCTOR CROSSSECTION [in mm2]
YStY YcStYc PN-EN 50525-2-51 2 ÷ 75 300/500V 0,5 ÷ 2,5
YoStY YStY-0 PN-EN 50525-2-51 2 ÷ 75 300/500V 0,5 ÷ 2,5
YStY YcStYc YStY-0 PN-EN 50525-2-51 3 ÷ 5 300/500V 4 ÷ 70
YKSLY YKSLY-P YKSLY-J PN-EN 50525-2-51 2 ÷ 75 300/300V 300/500V 0,5 ÷ 2,5

Application

Flexible cables with insulation and sheath from regular PVC (or heatresistant PVC for YvStYc) used as connection cables for control devices, machinery, tools of production and assembly lines, for installation as flexible cables with unrestricted movement. The jacket of YStY0, H05VV5F (NYSLÖ) cables is oilresistant.
SYMBOL STANDARD NO. OF CONDUCTORS VOLTAGE CONDUCTOR CROSSSECTION [in mm2]
YSLY-JZ YKSLY YKSLY-NR YKSLY-P NYSLY H05VV5-F (NYSLÖ) PN-EN 50525-2-51 2 ÷ 75 3 ÷ 5 300/500V 0,5 ÷ 2,54 ÷ 70

Application

Control cable with stranded conductors, PVC insulated and sheathed. Designed for connections in machinery and control devices and indoor installation, under various environmental conditions.
SYMBOL STANDARD NO. OF CONDUCTORS VOLTAGE CONDUCTOR CROSSSECTION [in mm2]
YSLY-JB YSLY-JZ YKSLY-NR YKSLY-P YKSLY-O DIN 0262 2 ÷ 75 2 ÷ 5 600/1000V 0,5 ÷ 2,54 ÷ 70

Application

Control cable with stranded copper conductors, PVC insulated and sheathed. Designed for operation in control circuits and for power supply. For fixed installation or moving connections. The cables are characterised by high flexibility and mechanical strength.
SYMBOL STANDARD NO. OF CONDUCTORS VOLTAGE CONDUCTOR CROSSSECTION [in mm2]
YSLCY-JZ YKSLYekw YKSLYekwo YKSLYekwo-P PN-EN 50525-2-51 2 ÷ 75 2 ÷ 5 300/300V 300/500V 0,5 ÷ 2,5 4 ÷ 70
NYSLCY H05VVC4V5-K (NYSLCYÖ) PN-EN 50525-2-51 2 ÷ 75 2 ÷ 5 300/500V 0,5 ÷ 2,5 4 ÷ 70

Application

Control cable with stranded copper conductors, PVC insulated and sheathed, with tinned copper wire screen. Used in situations where external fields may interfere with the signal or where the interference emitted by the cable has to be limited.
SYMBOL STANDARD NO. OF CONDUCTORS VOLTAGE CONDUCTOR CROSSSECTION [in mm2]
YSLY-JZ YKSLYekwo YKSLYekwo-P DIN 0262 2 ÷ 75 2 ÷ 5 600/1000V 0,5 ÷ 2,5 4 ÷ 70

Application

Control cable with stranded copper conductors, PVC insulated and sheathed. Used in situations where external fields may interfere with the signal or where the interference emitted by the cable has to be limited.
SYMBOL STANDARD NO. OF CONDUCTORS VOLTAGE CONDUCTOR CROSSSECTION [in mm2]
YSLYCY-JB YSLYCY-JZ YKSLYekwoy YKSLYekwoy-NR DIN VDE 0245, 0281 2 ÷ 75 2 ÷ 5 600/1000V 0,5 ÷ 2,5 4 ÷ 70

Application

Control cable with stranded copper conductors, galvanised copper wire screen, PVC inner sheath and PVC insulation and outer sheath. Used for I&C purposes in the machine industry, at production lines, plants, air conditioning systems, in metallurgical plants and steelworks. Used for medium exposure to mechanical stresses, for flexible connections without tensile stress and forced movements, installed in dry, damp and wet rooms and outdoors.
SYMBOL STANDARD NO. OF CONDUCTORS VOLTAGE CONDUCTOR CROSSSECTION [in mm2]
LiYY LiYY-NR LiYY-P DIN VDE 0245 DIN VDE 0812; 0814 2 ÷ 75 300/300V 300/500V 0,5 ÷ 1,5

Application

Control cable with stranded copper conductors, galvanised copper wire screen, PVC inner sheath and PVC insulation and outer sheath. Used for I&C purposes in the machine industry, at production lines, plants, air conditioning systems, in metallurgical plants and steelworks. Used for medium exposure to mechanical stresses, for flexible connections without tensile stress and forced movements, installed in dry, damp and wet rooms and outdoors.
SYMBOL STANDARD NO. OF CONDUCTORS VOLTAGE CONDUCTOR CROSSSECTION [in mm2]
LiYCY LiYCY-NR LiYCY-P DIN VDE 0245; 0812 2 ÷ 75 300/300V 300/500V 0,52 ÷ 751,5

Application

Cable with single stranded copper conductors with PVC insulation, common screen in the form of a tinned copper wire braid and PVC sheath. Designed for signal and data transmission. It is also used in electronic counters, control devices, controllers, office machines, etc., in the situations where screened cables with small dimensions are required.
Control cables, flexible, PVC insulated and sheathed Control cables, flexible, PVC insulated and sheathed Control cables, flexible, PVC insulated and sheathed Control cables, flexible, PVC insulated and sheathed Control cables, flexible, PVC insulated and sheathed Control cables, flexible, PVC insulated and sheathed Control cables, flexible, PVC insulated and sheathed Control cables, flexible, PVC insulated and sheathed
x