| SYMBOL |
STANDARD |
NO. OF CONDUCTORS |
VOLTAGE |
CONDUCTOR CROSSSECTION [in mm2] |
| YStY
YcStYc |
PN-EN 50525-2-51 |
2 ÷ 75 |
300/500V |
0,5 ÷ 2,5 |
| YoStY
YStY-0 |
PN-EN 50525-2-51 |
2 ÷ 75 |
300/500V |
0,5 ÷ 2,5 |
| YStY
YcStYc
YStY-0 |
PN-EN 50525-2-51 |
3 ÷ 5 |
300/500V |
4 ÷ 70 |
| YKSLY
YKSLY-P
YKSLY-J |
PN-EN 50525-2-51 |
2 ÷ 75 |
300/300V
300/500V |
0,5 ÷ 2,5 |
Application
Flexible cables with insulation and sheath from regular PVC (or heatresistant PVC for YvStYc) used as connection cables for control devices, machinery, tools of production and assembly lines, for installation as flexible cables with unrestricted movement. The jacket of YStY0, H05VV5F (NYSLÖ) cables is oilresistant.
| SYMBOL |
STANDARD |
NO. OF CONDUCTORS |
VOLTAGE |
CONDUCTOR CROSSSECTION [in mm2] |
| YSLY-JZ
YKSLY
YKSLY-NR
YKSLY-P
NYSLY
H05VV5-F
(NYSLÖ) |
PN-EN 50525-2-51 |
2 ÷ 75
3 ÷ 5 |
300/500V |
0,5 ÷ 2,54 ÷ 70 |
Application
Control cable with stranded conductors, PVC insulated and sheathed. Designed for connections in machinery and control devices and indoor installation, under various environmental conditions.
| SYMBOL |
STANDARD |
NO. OF CONDUCTORS |
VOLTAGE |
CONDUCTOR CROSSSECTION [in mm2] |
| YSLY-JB
YSLY-JZ
YKSLY-NR
YKSLY-P
YKSLY-O |
DIN 0262 |
2 ÷ 75
2 ÷ 5 |
600/1000V |
0,5 ÷ 2,54 ÷ 70 |
Application
Control cable with stranded copper conductors, PVC insulated and sheathed. Designed for operation in control circuits and for power supply. For fixed installation or moving connections. The cables are characterised by high flexibility and mechanical strength.
| SYMBOL |
STANDARD |
NO. OF CONDUCTORS |
VOLTAGE |
CONDUCTOR CROSSSECTION [in mm2] |
| YSLCY-JZ
YKSLYekw
YKSLYekwo
YKSLYekwo-P |
PN-EN 50525-2-51 |
2 ÷ 75
2 ÷ 5 |
300/300V
300/500V |
0,5 ÷ 2,5
4 ÷ 70 |
| NYSLCY
H05VVC4V5-K
(NYSLCYÖ) |
PN-EN 50525-2-51 |
2 ÷ 75
2 ÷ 5 |
300/500V |
0,5 ÷ 2,5
4 ÷ 70 |
Application
Control cable with stranded copper conductors, PVC insulated and sheathed, with tinned copper wire screen. Used in situations where external fields may interfere with the signal or where the interference emitted by the cable has to be limited.
| SYMBOL |
STANDARD |
NO. OF CONDUCTORS |
VOLTAGE |
CONDUCTOR CROSSSECTION [in mm2] |
| YSLY-JZ
YKSLYekwo
YKSLYekwo-P |
DIN 0262 |
2 ÷ 75
2 ÷ 5 |
600/1000V |
0,5 ÷ 2,5
4 ÷ 70 |
Application
Control cable with stranded copper conductors, PVC insulated and sheathed. Used in situations where external fields may interfere with the signal or where the interference emitted by the cable has to be limited.
| SYMBOL |
STANDARD |
NO. OF CONDUCTORS |
VOLTAGE |
CONDUCTOR CROSSSECTION [in mm2] |
| YSLYCY-JB
YSLYCY-JZ
YKSLYekwoy
YKSLYekwoy-NR |
DIN VDE 0245, 0281 |
2 ÷ 75
2 ÷ 5 |
600/1000V |
0,5 ÷ 2,5
4 ÷ 70 |
Application
Control cable with stranded copper conductors, galvanised copper wire screen, PVC inner sheath and PVC insulation and outer sheath. Used for I&C purposes in the machine industry, at production lines, plants, air conditioning systems, in metallurgical plants and steelworks. Used for medium exposure to mechanical stresses, for flexible connections without tensile stress and forced movements, installed in dry, damp and wet rooms and outdoors.
| SYMBOL |
STANDARD |
NO. OF CONDUCTORS |
VOLTAGE |
CONDUCTOR CROSSSECTION [in mm2] |
| LiYY
LiYY-NR
LiYY-P |
DIN VDE 0245
DIN VDE 0812; 0814 |
2 ÷ 75 |
300/300V
300/500V |
0,5 ÷ 1,5 |
Application
Control cable with stranded copper conductors, galvanised copper wire screen, PVC inner sheath and PVC insulation and outer sheath. Used for I&C purposes in the machine industry, at production lines, plants, air conditioning systems, in metallurgical plants and steelworks. Used for medium exposure to mechanical stresses, for flexible connections without tensile stress and forced movements, installed in dry, damp and wet rooms and outdoors.
| SYMBOL |
STANDARD |
NO. OF CONDUCTORS |
VOLTAGE |
CONDUCTOR CROSSSECTION [in mm2] |
| LiYCY
LiYCY-NR
LiYCY-P |
DIN VDE 0245; 0812 |
2 ÷ 75 |
300/300V
300/500V |
0,52 ÷ 751,5 |
Application
Cable with single stranded copper conductors with PVC insulation, common screen in the form of a tinned copper wire braid and PVC sheath. Designed for signal and data transmission. It is also used in electronic counters, control devices, controllers, office machines, etc., in the situations where screened cables with small dimensions are required.